Hifair™ Advanced One Step RT-qPCR Kit _11175ES

YeasenSKU: 11175ES20

Size: 20T
Price:
Sale price$40.00

Shipping calculated at checkout

Stock:
In stock (11 units), ready to be shipped
Bulk Quote Inquiry

Description

Hifair Advanced One Step RT-qPCR Kit is a kit for fluorescence quantification based on SYBR Green I dye. Using gene-specific primers, reverse transcription and qPCR reactions are completed in one tube, eliminating the need for repeated cap-opening and pipetting operations, greatly improving assay efficiency and reducing the risk of contamination. For RNA samples, the kit employs heat-resistant Hifair V Reverse Transcriptase for efficient cDNA synthesis and UNICON HotStart Taq DNA Polymerase for quantitative amplification. Under the optimized buffer system, the sensitivity of the kit can be as high as 0.1 pg for highly expressed targets and as high as 1 pg for moderately expressed targets, and the kit is also suitable for amplification and quantification of DNA samples. The kit is suitable for the amplification and quantification of DNA samples. It enables the sensitive detection and quantification of nucleic acids from different plant and animal samples, cells and microorganisms.

Specifications

Cat.No.

11175ES20 / 11175ES70

Size

20 T/200 T

Components

Components No.

Name

11175ES20

11175ES70

11175-A

2× Hifair Advanced SG Buffer

250 μL

2×1.25 mL

11175-B

Hifair Advanced UH Enzyme Mix

20 μL

200 μL

11175-C

Hieff SP High Rox

10 μL

100 μL

11175-D

RNase Free H2O

250 μL

2×1.25 mL

Storage

This product should be stored at -25~-15℃ away from light for 1 year.

Instructions

  1. Reaction system configuration*****

Components

Volume (μL)****

Volume (μL)

Final concentration

2× Hifair Advanced SG Buffer*

12.5

25

Hifair Advanced UH Enzyme Mix

1

2

-

Forward Primer (10 μmol/L)**

0.5

1

0.2 μmol/L

Reverse Primer (10 μmol/L)**

0.5

1

0.2 μmol/L

RNA***

X

X

-

RNase Free H2O

to 25

to 50

-

* Low Rox models and models without Rox correction are prepared directly according to the above reaction system. When using the High Rox model, add Hieff™ SP High Rox to 2 x Hifair™ Advanced SG Buffer at 1:250 v/v, mix well and centrifuge. The 2× Hifair Advanced SG Buffer with Hieff™ SP High Rox does not affect the use of the Low Rox and No Rox correction models.

** The final primer concentration was 0.2 μmol/L, which could also be adjusted between 0.1 and 1 μmol/L as appropriate.

*** The reagent is extremely sensitive, with Total RNA in the range of 1 pg-1 μg, and testing of human samples showed an optimal input of 1 pg-100 ng, controlling for an overall Ct value in the range of 15-30 as appropriate.

**** It is recommended to use 20 μL or 50 μL to ensure the validity and reproducibility of target gene amplification.

***** Please prepare in the ultra-clean bench and use nuclease residue-free tips and reaction tubes; tips with filter cartridges are recommended. Avoid cross contamination and aerosol contamination.

2)Reaction program

Cycle step

Temp.

Time

Cycles

Reverse transcription

50℃*

6 min

1

Initial denaturation

95℃

5 min

1

Amplification reaction

95℃

15 sec

40

60℃**

30 sec

Melting curve stage

Instrument Defaults

1

*The reverse transcription temperature can be selected between 50-55°C according to the experimental needs. For DNA samples, the reverse transcription process can be omitted.

** In special cases the annealing/extension temperature can be adjusted according to the primer Tm value, 60°C is recommended.

3)Applicable Model

Instrument models that do not require Rox calibration:

Bio-Rad: CFX96, CFX384, iCycler iQ, iQ5, MyiQ, MiniOpticon, Opticon, Opticon 2, Chromo4;

Eppendorf: Mastercycler ep realplex, realplex 2 s;

Qiagen: Corbett Rotor-Gene Q, Rotor-Gene 3000, Rotor-Gene 6000;

Roche Applied Science: LightCycler 480, LightCycler2.0, Lightcycler 96;

Thermo Scientific: PikoReal Cycler; Cepheid: SmartCycler; Illumina: Eco qPCR;

Low Rox applicable models:

ABI 7500, 7500 Fast, ViiA7, QuantStudio 3 and 5, QuantStudio 6, 7, 12k Flex;

Stratagene MX3000P, MX3005P, MX4000P;

High Rox applicable models*:

ABI 5700, 7000, 7300, 7700, 7900HT Fast, StepOne, StepOne Plus.

* For High Rox models, note that Hieff™ SP High Rox should be added proportionally to 2 x Hifair Advanced SG Buffer before use.

 Notes

  1. This product is for research use only.
  2. Please operate with lab coats and disposable gloves,for your safety.


Documents:

Manuals

You may also like